Medical Guidewire PTFE Coated Zebra Hydrophilic
Our Medical Guidewire PTFE Coated Zebra Hydrophilic is designed for catheter navigation applications in minimally invasive medical devices.The guide wire consists of a flexible metal core, PTFE low-friction coating, zebra radiopaque marking, and optional hydrophilic coating.With customized diameter, length, tip design, and coating options, we provide OEM guide wire solutions for medical device manufacturers.

Medical Guidewire PTFE Zebra Hydrophilic Feature
Competitive advantage
The company conducted a competitive advantage analysis to identify its strengths and weaknesses compared to its rivals.
industry-leading
Five years of electronic mechanical products precipitation,products mature and stable
01
High market share
Benchmarking machinery has great influence,covering 1,500 companies and 15 well-known enterprises across the country
02
High market share
Benchmarking machinery has great influence,covering 1,500 companies and 15 well-known enterprises across the country
03
Perfect product system
Electronic + technology solutions,complete product architecture system
04
Efficient after-sales service
To provide customers with a range of product services,24 hours online
05
Competitive advantage
The company conducted a competitive advantage analysis to identify its strengths and weaknesses compared to its rivals.
industry-leading
Five years of electronic mechanical products precipitation,products mature and stable
01
High market share
Benchmarking machinery has great influence,covering 1,500 companies and 15 well-known enterprises across the country
02
High market share
Benchmarking machinery has great influence,covering 1,500 companies and 15 well-known enterprises across the country
03
Perfect product system
Electronic + technology solutions,complete product architecture system
04
Efficient after-sales service
To provide customers with a range of product services,24 hours online
05
Low Friction PTFE Coating
PTFE coating provides a smooth surface and helps reduce friction between the guide wire and catheter.
01
Hydrophilic Coating Option
The hydrophilic coating becomes lubricious when activated by liquid, supporting smoother guide wire movement.
02
Zebra Radiopaque Marking
Zebra marking helps improve visibility under X-ray imaging during medical procedures.
03
Flexible Core Design
Stainless steel or nitinol core options are available to meet different requirements for flexibility and torque control.
04
Customized Tip Configuration
Straight tip, J tip, and other customized tip designs are available according to customer requirements.
05
Production Process




Advantages of Our Medical Guide Wire
Customized Manufacturing Capability
We can customize guide wire diameter, length, coating structure, and tip design based on customer drawings or application requirements.
Complete Production Process
Our production capability covers core wire preparation, PTFE coating, marking, hydrophilic coating, tip forming, inspection, and packaging.
Suitable for Medical Device Development
We support prototype development and customized production for catheter and minimally invasive medical device projects.
Medical Ptfe Zebra Guide Wire Applications

PTFE coated hydrophilic guide wires are commonly used as supporting components in catheter-based medical devices, including urology, cardiovascular, and endoscopic applications.
FAQ
Q: What is a PTFE coated zebra hydrophilic guide wire?
A: A PTFE coated zebra hydrophilic guide wire is a flexible medical wire with PTFE coating, zebra marking, and hydrophilic coating designed for catheter navigation applications.
Q: What materials are used for medical guide wire cores?
A: Common core materials include stainless steel and nitinol. The selection depends on flexibility, torque response, and application requirements.
Q: What is the function of PTFE coating on a guide wire?
A: PTFE coating provides a smooth low-friction surface, helping the guide wire move more easily inside the catheter.
Q: Why does the guide wire have zebra markings?
A: Zebra markings improve visibility under X-ray imaging and help operators identify the guide wire position
Q: What is the purpose of hydrophilic coating?
A:Hydrophilic coating becomes smoother when exposed to liquid, helping reduce resistance during guide wire movement.
Q: Can you customize guide wire diameter and length?
A: Yes. Diameter, length, tip design, coating type, and marking pattern can be customized according to customer requirements.
Specification of Hydrophilic Guidewires
|
OD Size (Inch) |
Length (cm) |
Tip Design |
Description |
Sterilization Methods |
|
0.018'' |
150 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.025'' |
150 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.028'' |
150 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.032'' |
150 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.035'' |
150 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.038'' |
150 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.018'' |
180 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.025'' |
180 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.028'' |
180 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.032'' |
180 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.035'' |
180 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.038'' |
180 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.018'' |
260 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.025'' |
260 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.028'' |
260 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.032'' |
260 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.035'' |
260 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.038'' |
260 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.018'' |
450 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.025'' |
450 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.028'' |
450 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.032'' |
450 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.035'' |
450 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |
|
0.038'' |
450 |
3cm Straight |
PTFE-Nitinol Guidewire with Hydrophilic Tip |
Autoclave/ETO/Gamma radiation |